Automated Blood Typing Analyzer
Cardina-3000A
Column Agglutination Method

  • Hits:89
  • Time:2025-9-4

Details

Automated Blood typing Analyzer is suitable for Micro-column gel method,which is simple to operate, high sensitivity, can detect low content of antigen and antibody,the results are clear and reliable, easy to store, and meet the requirements of a variety of data management.

Analyzer is suitable for automatic detection of forward and reverse ABO blood group typing, Rh blood group identification,irregular antibody screening and cross-matching in various hospitals, blood banks and centers of disease control and prevention.

Sample scanning,micro-column card loading,sample addition, dilution reagent addition, incubation, centrifugation and result interpretation were all completed automatically without manual intervention.

General Features

  • Advanced modular design.Vertical structure. Layered setting.
  • The micro-column gel method was used and compatible with both 6-hole and 8-hole cards.
  • Barcode management to achieve the full traceability of specimen and reagent and result.
  • Micro-column gel card precentrifugation is supported. Emergency specimens are preferentially treated.
  • Support cyclic injection. Continuous card. Multi-item parallel detection.
  • CCD image acquisition device and processing software were used to assist the interpretation of the results.
  • Connected to the hospital LlS or HlS system to realize two-way communication.

Supporting Micro-column Gel Card

  • ABO positive typing card and RhD blood group testing card
  • ABO positive/reverse typing and RhD typing cards(micro-column gel method)
  • Rh blood group antigen test card (micro-column gel method)
  • Anti-human globulin(anti-lgG + C3d) test card (micro-column gel method)

Technical Parameters

Cardina-3000A

Test Project

1.ABO blood group positive typing test2.ABO blood group reverse typing test3.Rh(D)blood group typing test4.Cross matching of blood test5.Antibody Screening test6.Rh typing test

Functional Use

Sample scanning, micro-column loading, sample addition, dilution, reagent addition, incubation, centrifugation, and result interpretation were all completed automatically without manual intervention.

Mode of Operation

Cyclic injection, card continuous injection; Multi-item parallel detection can customize the test item of each sample, and submit ABO forward and reverse typing, Rh D typing, irregular antibody, cross matching and other test items for a batch of samples at the same time.

Test Carrier

Micro-column gel card (use both 6-hole and 8-hole micro-column gel cards)

Speed of Processing

Blood typing test 600 per hour

Antibody screening test 576 per hour

Position of Sample

96.The original specimen tube was loaded on the machine. Automatic entry and exit of the sample holder. Sample cycle replenishment

Reagent Position

14,Automatic mixing reagent.Automatic identification of reagent position

Position of Card

144. Can be loaded once

Bar Code Scanning

Sample and micro-column gel card and reagent bottle automatic scanning. Support a variety of bar codes

Robotic Arm

Three independent robotic arms, two are sampling arms, and one is robotic arm

Sample Loading Channel

Two sample loading channel, Adopts permanent sampling needle to avoid the cost of sampling needle consumables, and has the function of blocking needle alarm

Mechanical Grasper

One independent mechanical claw, with card drop alarm function

Accuracy of Sampling

Adding amount(μl)                  CV                 True degree

10                                    3%                   1μl

50                                    2%                       2μl

Amount of Liquid Added

1μl~ 500μl

Position of Incubation

Four independent incubation tables. 48 incubation sites total. Target temperatures ≤±2

Centrifugal Position

Two 12 card independent centrifuges.Rotating speed 0-3800 RPM

System of Interpretation

High-resolution color CCD imaging interpretation, Real and clear pictures. The original image can be saved permanently

Bar Code Printer

Reagent name and validity printing

Mode of Operation

Support pre-centrifugation of micro-column card, Continuous supplementary loading of sample and reagent and micro-column card, Emergency insertion

Puncture

Independent puncture module, Puncture and sample addition and card removal were carried out simultaneously and side by side without interference

Liquid Volume Detection

The Buid volume was monitored in real time and displayed in the software interface Automatic alarm when liquid volume is insufficient or waste liquid volume is excessive

Protection of Security

Fully closed appearance structure, Dual alarm system with sound and indicator light

Operate System and Software

WIN11 Chinese operating system, MYSQL data base, can be connected with LIS/ HIS system to achieve two-way communication

Operate Environment

Temperature 15°C~ 30°C Humidity30%-75%

Power

AC 220V±22V 50Hz±1Hz

Instrument Size

920*760*1800mm (Length*Width*Height)

Weight

200kg